Home / Collections / Inspection and Mapping Drones / FLIR MUVE™ C360 INTEGRATED MULTI-GAS DETECTOR FOR DJI M210

FLIR MUVE™ C360 INTEGRATED MULTI-GAS DETECTOR FOR DJI M210

$13,000.00
FLIR MUVE™ C360 INTEGRATED MULTI-GAS DETECTOR FOR DJI M210

FLIR MUVE™ C360 INTEGRATED MULTI-GAS DETECTOR FOR DJI M210

$13,000.00
description

The FLIR MUVE™ C360 is a multi-gas detector completely integrated with an unmanned aerial system (UAS) to provide real-time continuous monitoring of chemical hazards while on the move. The sensor block boasts 8-channels, which includes a photoionization detector (PID), Lower Explosive Limit (LEL) detector, and five other electrochemical sensors. The MUVE C360 sensor block quickly latches to a proprietary integration dock mounted to the UAS. The FLIR calibration station features the same dock, so the operator can easily connect for routine sensor verification. Sensor readouts are prioritized based on alarm conditions and are displayed real-time through the pilot’s user interface. The MUVE C360 is a time-saving, game-changer for emergency responders, industrial safety officers, and environmental monitoring experts.

 

SYSTEM OVERVIEW
Sensors
CO, Cl₂, O₂, NO₂, H₂S, SO₂, LEL
PID
VOC 10.6 eV (ppm)
Display & Alerts
FLIR VueLink™ application integrated via tablet connected to the UAS remote controller
Total Weight Payload
1.5 lb (680.39 g) - C360 with dock and snorkel
ENVIRONMENTAL
Operating Temp & Humidity
-4 to 122 °F (-20 to 50 °C) 10 to 93%, non-condensing
Storage Temperature
-22 to 158 °F (-30 to 70 °C)
Environmental Protection
IP43-rated
PHYSICAL FEATURES
Compatibility
Currently compatible with DJI Matrice 210, V1 and V2, UAS
Dimensions (L x W x H)
6.5 x 2.3 x 2.0" (16.51 x 5.84 x 5.08 cm) - C360 only
Integration Dock
Proprietary quick-connect mount for UAS and FLIR Calibration Station
POWER
Battery Specs
Powered by the UAS
Cold Start Time
90 seconds from cold start
Input Voltage
24V DJI Matrice 210; 12V FLIR Calibration Station
SAMPLING & ANALYSIS
Sample Introduction
Actively pumped via integrated snorkel
Sampling & Analysis
Real-time detection
Sampling Rate
300 ml/min minimum
SENSOR BLOCK TECHNOLOGY
FLIR Calibration Station
Proprietary automatic calibration design, includes four (4) gas regulators, tubing, and power adaptor
SYSTEM INTERFACE
Communication
Remote controller via USB-A accessory (tablet); UAS power port and serial (C360)
Data Storage
Sensor data and flight information logged on tablet
Training Requirements
<30 mins for operator; 4 hours for advanced user
Wireless Range
Determined by the UAS range