The RMUS Optical Gas Detection Drone is a Ready to Deploy™ package featuring ICI's Mirage HC Infrared Camera.   The Mirage can detect Methane, Propane, Benzene, Butane and many other hydrocarbon gases (see list below).

All RMUS packages include up-to-date firmware updates, everything you'll need to begin deploying the drone immediately, access to the RMUS intro/systems training video and access to a phone consultation with our technicians. 

RMUS Optical Gas Detection Drone includes:

        • Ready to Deploy™ DJI Matrice M600 pro with Return to Home, GPS Altitude Hold, Intelligent Orientation Control, and Auto Takeoff/Landing functions
        • ICI Mirage HC 640x512 IR Camera (see below for more specs and gases detected) - Camera can be removed from Drone for handheld use
        • ICI Sensor Control Module
        • ICI RC10 Visible Light Camera
        • Mirage HC IR Camera and RC10 Visible Light Camera are mounted on one gimbal for remote operation on the UAV
        • ICI IR Flash Professional Thermal Imaging Software
        • Apple iPad mini 4 128GB
        • Marco Polo System (helpful in finding lost drones)
        • Go Professional Case (Matrice M600 Pro Case)
        • Rapid Charging Station (charge 4 batteries, 2 remotes, 2 tablets simultaneously)
        • Additional Remote for camera operator
        • 12 spare TB48S Batteries (6 TB47S batteries are included with for a total of 18 batteries
        • 6 DJI Matrice M600 spare propellers
        • RMUS ICI Optical Gas Detection Drone Training -- Mandatory for this package - RMUS trains on: basic maintenance, battery care, camera care, app usage, software usage and correctly using the Mirage HC.

Add-ons (additional cost):

      • Drone Deploy -- Autopilot and Mapping/Imaging/modeling software.

ICI Mirage HC Specs:

  • Detector Array: Cooled MWIR InSb
  • Pixel Pitch: 15µm
  • Pixel Resolution: 640 x 512
  • Spectral Band: 3.2µm – 3.4µm
  • NETD Sensitivity: <.025°C at 30°C
  • Frame Rate:
    • 30Hz
    • 25Hz
  • Dynamic Range:
    • 8 bit
    • 14 bit
  • Operation Range: -40°C to 80°C
  • Temperature Range: -55°C to 80°C
  • Accuracy: +/- 1°C
  • Pixel Operability: >99%
  • 20G Shock / 5.8G Vibration
  • Dimensions: 154mm x 60mm x 90mm – without lens
    (LxWxH +/- .5mm)
  • Weight: <765 Grams – without lens
  • Video: NTSC or PAL analog video
  • Humidity: non-condensing b/t 5%-95%
  • Power: 12V (Cooling Engine)
  • USB 2.0 for Electronics Power & Data
  • Shutterless
  • Aluminum Enclosure

Detectable Gases:

  • Benzene – 3.5g/hr
  • Ethanol – 0.7g/hr
  • Ethylbenzene – 1.5g/hr
  • Heptane – 1.8g/hr
  • Hexane – 1.7g/hr
  • Isoprene – 8.1g/hr
  • Toluene – 3.8g/hr
  • Methanol – 3.8g/hr
  • MEK – 3.5g/hr
  • Pentane – 3.0g/hr
  • Xylene – 1.9g/hr
  • Butane – 0.4g/hr
  • Ethane – 0.6g/hr
  • Methane – 0.75g/hr
  • Propane – 0.4g/hr
  • Ethylene – 4.4g/hr
  • Propylene – 2.9g/hr
  • MIBK – 2.1g/hr
  • Octane – 1.2g/hr
  • 1-Pentene – 5.6g/hr